Feedback Integrated Solutions

Occupant Load & Evacuation Time Estimator

NFPA/IBC load factors (advisory) • Preliminary egress time model
Back to Tools

Project Information (optional)

Occupant Load

If you leave the Load Factor empty, the tool will apply a typical advisory value for the selected use type.

Egress / Evacuation Parameters

Simplified movement model: total people = people per floor × storeys; effective speed = min(entered speed, 1.4 − 0.37 × density); time = travel distance / effective speed + total people / (density × effective speed × effective exit width). Time is converted from seconds to minutes. Area is per floor; all storeys are assumed to share the entered effective bottleneck width. This is not a complete evacuation assessment: pre-movement, stairs, smoke, assisted evacuation and merging are not modeled.